Product Code : GA 150
Product Description

Our strict quality controllers keep a close watch on the production process so that we can provide impeccable range of Trigas Analyzer. This is specifically designed to analyze the atmosphere inside of a hydrogen-cooled power generator during purity and purge modes. It is also designed for monitoring H2 purity inside a power generator and further monitors the purging procedure during a generator shut down or start up. In addition, this Trigas Analyzer can be availed from us at affordable prices.

Features:

  • High in functionality
  • Power efficient
  • Longer service life

Specifications:

  • Ranges : 0-100%H2inAir, 0 -100% C02 in Air, 0 -100% H2 in C02 (Optional)
  • Sensor Type: Thermal Conductivity
  • Resolution: 0.1% (gas) H2, Air and C02
  • Response Time: 0-90% in less than 10 seconds @ 0.5 SCFH
  • Drift Rate: Less than 1% (range)
  • Display: Alpha Numeric LCD
  • Flow Rate: 0.1-2.5 SCFH Normal, 2.5 SCFH maximum, (0.5 - 30 psig)
  • Flow Meter: Required
  • Wetted Part: Brass, SS, Aluminum, Nylon
  • Operating Temperature: 0 - 60°C
  • Certification: Intrinsically Safe
  • Gas Connections: 1/4 Tube
  • Accessories: Battery Charger, Operation Manual
  • Power: 12 VDC Battery Inbuilt


Our strict quality controllers keep a close watch on the production process so that we can provide impeccable range of Trigas Analyzer. This is specifically designed to analyze the atmosphere inside of a hydrogen-cooled power generator during purity and purge modes. It is also designed for monitoring H2 purity inside a power generator and further monitors the purging procedure during a generator shut down or start up. In addition, this Trigas Analyzer can be availed from us at affordable prices.

Features:

  • High in functionality
  • Power efficient
  • Longer service life

Specifications:

  • Ranges : 0-100%H2inAir, 0 -100% C02 in Air, 0 -100% H2 in C02 (Optional)
  • Sensor Type: Thermal Conductivity
  • Resolution: 0.1% (gas) H2, Air and C02
  • Response Time: 0-90% in less than 10 seconds @ 0.5 SCFH
  • Drift Rate: Less than 1% (range)
  • Display: Alpha Numeric LCD
  • Flow Rate: 0.1-2.5 SCFH Normal, 2.5 SCFH maximum, (0.5 - 30 psig)
  • Flow Meter: Required
  • Wetted Part: Brass, SS, Aluminum, Nylon
  • Operating Temperature: 0 - 60°C
  • Certification: Intrinsically Safe
  • Gas Connections: 1/4 Tube
  • Accessories: Battery Charger, Operation Manual
  • Power: 12 VDC Battery Inbuilt


Contact Us

25/N, Laxmi Industrial Estate, New Link Road, Andheri (W), Mumbai, Maharashtra, 400053, India
Phone :+917042398952