0
home

Broken Filter Bag Detector PM-251

home
Broken Filter Bag Detector PM-251
Broken Filter Bag Detector PM-251
Price And Quantity
  • Piece/Pieces
  • 2
  • Piece/Pieces
  • 30000.00 - 70000.00 INR
    Product Specifications
    • Flameproof
    • 3/4" NPT
    • 95% Rh non condensing type
    • IIA, IIB
    • Stack gas application
    • 100-500 Millimeter (mm)
    • Grey
    • 1000 mg/m3
    • 300 Celsius (oC)
    • 24 V DC Volt (v)
    • 110-230 V AC, 50 Hz or 24 V DC
    • 120X120 Millimeter (mm)
    • Insitu
    • 1.5 Kilograms (kg)
    • Digital Only
    • 0-1000 mg/m3
      Product Description
      Broken Filter Bag Detector PM-251 is widely used in different applications where detection and management of dust levels is important. It is used to ensure complete safety, proper maintenance and high efficacy of plant. This dependable and economical device is used to detect leakage and filter failures in bulk solids industries. It comes with modern LED visual indication along with a relay output to get the most out of its user-friendly design. It has adjustable damping system to enhance the response time and ensure false alarms. In addition to this, it is a trustworthy Flow / No-flow detector ideal for process flow applications to monitor flow disruptions of dry solids in pneumatic conveying applications. This timely-tested device precisely measures the tribo-electric effect as well as calculates the particle emissions activity when exceeded the acceptable levels.

       Features of Broken Filter Bag Detector PM-251

      •     Actual particulate measurement
      •     Adjustable sensitivity and time delay
      •     Direct sensing method
      •     Easy installation with a range of duct sizes from 250 mm to 2 m
      •     Field-proven device available with tribo-electric technology to ensure reliability
      •     Ideal to be used for virtually all dust collectors
      •     Integral assembly of sensor

      Technical Specifications:

      Technique

      Tribo - Electric charge transfer

      Sensitivity

      Adjustable

      Operating Temp (Ambient)

      -20 to 70C

      Flue Gas Temperature

      0-250C (upto 1000C Opt)

      Ranges

      1-1,000 mg/m3

      Response Time

      Instantaneous

      Duct Width

      50 mm to 2.2 m

      Positioning

      90C to Duct Wall

      Communications Path Length

      Up to 1,000 meters

      Socket

      Single 1 Flat Flanged Fitting

      Mounting Details

      Dia 40 mm, Quick Disconnect Fitting With Clamp And Gasket

      Construction

      316 Grade Stainless Steel

      Sensor Length

      25, 100, 200, 500, 1000 mm or customised

      Insulation

      PTFE (T Model - Glass Ceramic)

      Sensor Diameter

      10 mm

      Power Supply

      24 V DC

      Output

      4-20 mA

      Alarms

      Green - Normal
      Yellow - Warning
      Red - High Alarm

      Alarm Delay

      Adjustable up to 10min

      Averaging Time

      Programmable Up to One Hour

      Output - Remote Alarm

      SPDT Relay 24 V DC 5 mA

      Power Supply

      110/220 Volts 50 Hz AC or 24 V DC

      Technical Details 

      Trade Information
      • Telegraphic Transfer (T/T)
      • 10 Per Month
      • 3 Week
      • Western Europe, Middle East, Asia, Eastern Europe, Africa
      • All India
      • CE , CMRI
        Related Products


        Send Inquiry


        Send Inquiry


        Send Inquiry


        Send Inquiry


        Send Inquiry


        Send Inquiry
        right arrow
        left arrow
        Contact Us

        25/N, Laxmi Industrial Estate, New Link Road, Andheri (W), Mumbai, Maharashtra, 400053, India
        Phone :+918037302133